How to Package an Ash-Loaded RECD Filter for Off-Site Cleaning

A ceramic filter element that has run for a few thousand hours looks tougher than it is. It is heavy in the hand, wrapped in a steel can, and covered in grey dust. Then somebody sets it down on a concrete floor a little too firmly, or tips it into the back of a pickup with a spare tyre, and the honeycomb inside quietly cracks. Nothing looks wrong. The workshop finds the damage three days later, and the argument about who broke it begins.

That argument is avoidable. If you have decided on off-site cleaning, the job of getting the element to the workshop is a small project in its own right, and it deserves its own plan. This guide shows how to package an RECD filter for cleaning so that it arrives intact, does not shed ash along the way and comes with enough records to settle any dispute.

We follow one element through eight legs of a custody route, from the moment you decide to remove it until you accept it back. Each leg has a purpose, a short list of actions and a hold point. You will also find a packing specification table, a tag sheet you can print, a short worked comparison of packing cost against damage cost and three illustrative failure stories.

A note on scope. RECD designs differ. Some have a removable cartridge, some a canister that must be unbolted from the exhaust line, some a segmented core. Your supplier’s removal and handling procedure always comes first. Everything below is general good practice that sits on top of it. If the supplier says “do not do this”, do not do this.

Why packing deserves a plan

Three things make an ash-loaded element different from an ordinary spare part.

It is fragile in a way that does not show. The honeycomb inside the can is a ceramic with thin walls. A cracked element can still look fine from outside. California’s air regulator, in a handbook for owners of filters fitted to vehicles, warns that the filter appears rugged but is commonly made from ceramic, and advises that it should never be banged or tapped because that could crack the element (CARB DPF handbook). A road shock in transit is just a bigger tap.

It carries loose material. Ash and soot are fine particulates. Tilt or shake an element and a surprising amount works loose. In a closed vehicle that becomes a dust problem. In a plant room it becomes an exposure problem for whoever is next to it.

Responsibility is often vague. A truck maker’s service bulletin on sending filters to a cleaning contractor says plainly that damage caused by shipping is the dealership’s responsibility, and it recommends packing the filter first in a smaller box and then in a larger box surrounded by packing material (NHTSA-filed service bulletin). Your contract with a cleaning provider may say the opposite, or nothing at all. Settle that before the element moves.

The eight-leg route at a glance

LegNamePurposeHold point before moving on
0PlanAgree method, responsibility, route, dateWritten scope and handling terms received
1Isolate and coolMake the DG set and exhaust safe to work onLock-out and cool-down confirmed
2Capture the “before” stateReadings, photographs, identificationBefore-pack complete and filed
3Remove and first sealTake the element out and contain the dustBoth faces capped, no loose ash showing
4Inner packProtect the element from shock and moistureElement immobilised inside bag and inner box
5Outer crateAdd a second shell and cushioningNothing moves when the crate is shaken gently
6Label and documentMake the package identifiable and traceableTag sheet and custody sheet signed
7Transport and receiptMove it and hand it overReceipt inspection signed by the workshop
8Return inspectionAccept the cleaned elementReturn inspection signed before refit

Legs 7 and 8 matter as much as the first six. A well-packed element that is handed over without a signature is still an unresolved liability.

Leg 0: Plan the movement before touching the exhaust

Spend twenty minutes on paper and you will save hours on site.

Confirm what is leaving. Is it the ceramic element alone, the element in its can, or the whole RECD body? Some cleaning contractors want only the filter core and will charge extra to remove a catalyst section or other parts that have been left attached. The service bulletin mentioned above makes this point for oxidation catalysts that were left on a filter sent for cleaning. Agree in writing what travels.

Agree what stays behind. Gaskets, clamps, heat shields and sensors normally stay with you, or are replaced, but the answer depends on the provider and the design. Our article on cleaning an RECD filter without removing its sensors covers sensors in detail. Heat shields and insulation are worth tagging and keeping safe; see insulation and heat shields in an RECD site plan.

Settle responsibility for damage in transit. Who insures the journey? Who packs? If the provider supplies a transport crate, who inspects it? Write the answer into the order or the quotation. Our guide to what a cleaning service quotation should include lists the clauses to look for.

Plan the lift and the route. Know the element’s weight from the datasheet or from a bathroom-scale check on a similar spare, plus an allowance for ash. Decide who lifts, with what, and which route avoids stairs, narrow doors and wet floors. For a rooftop device, plan the lifting arrangement in advance; see rooftop RECD installation: structural support and lifting access. Check clearance around the unit too, as described in service clearance around an RECD.

Arrange cover. If the DG set protects a critical load, decide how it will be covered while the element is away: an exchange element, a shared spare or a scheduled outage. See also an RECD fault business continuity plan.

Gather the packing materials in advance. The table in the next section gives a list. Do not start unbolting anything until the crate, the bags and the tape are in the room.

A packing specification table

The table below is a starting specification. Adjust it to your element’s size and weight and to the provider’s requirements. Values marked “illustrative” are examples, not engineering limits.

ItemPurposeNotes
Face caps or rigid discs (two)Cover inlet and outlet facesRigid, larger than the face, secured by tape around the can. Never rely on cling film alone
Heavy-duty polythene bag, 150 micron or thicker (illustrative)Contain loose ash and sootChoose a bag long enough to fold the neck over and tape twice
Second bagDouble containmentInserted after the first has been wiped clean on the outside
Foam sleeve or corrugated wrapCushion the sidesThick enough that a fist pressed against the wrap does not reach the can
Inner boxFixes position, protects against knocksInterior sized so the wrapped element cannot slide
Outer box or crateSecond shellLeave a cushioning gap of several centimetres on all sides
Cushioning materialFill voidsDense foam or moulded pulp is better than loose chips that settle
Strapping and tapeKeep lids closedStrapping around the crate, tape on seams
Arrow stickers and “fragile, ceramic” labelsOrientation and handlingMark the inlet and outlet directions
Tamper seals (numbered)Show the pack was not opened in transitRecord the numbers on the custody sheet
Document pouchKeeps paperwork with the packageStuck to the outside, not inside the sealed bags
HEPA-fitted vacuum, damp cloths, PPEClean the exterior and protect peoplePPE for respiratory protection, gloves, eye protection and coveralls

Leg 1: Isolate, cool and make the area safe

Exhaust components hold heat for a long time. A cleaning job that begins on a warm device is a burn waiting to happen, and a warm element placed in a plastic bag is a fire and melt hazard.

  1. Stop and isolate the DG set following your site’s lock-out and permit-to-work procedure. Isolate the RECD controller and any heater supply.
  2. Wait for cool-down until the exhaust and the RECD body are safe to touch. Use a contact thermometer if the site has one, rather than a hand.
  3. Ventilate the area and lay a sheet or tray under the work zone to catch ash.
  4. Brief the team: who lifts, who photographs, who vacuums, who records.

Hold point. The area is isolated, cool and covered, and everyone has PPE on.

Leg 2: Capture the “before” state

You cannot argue about damage you did not record. Take these steps before anything is loosened.

  • Read and record pressure at the reference load (before shutting down, if the set is running), with date, load and run hours. This is the same reading used in the cleaning decision. See comparing RECD pressure readings at different generator loads.
  • Photograph the installed device, the sensor connections, the clamps and the insulation, with a scale reference. These pictures are also your reassembly guide.
  • Record identification: RECD model and serial number, element ID or batch if marked, DG set ID, site and date.
  • Record the history: run hours since installation and since the last cleaning, plus any alarms or failed regenerations. Our RECD event log guide shows the fields.
  • Mark the flow direction. The element must go back the same way. The US Environmental Protection Agency’s guidance on filter maintenance notes that the filter must be reinstalled in the correct flow direction (EPA 420-F-10-027). Use arrows on the can, and a photograph of the arrow beside a landmark such as the inlet flange.
  • Mark the clocking. If the can has a rotational position relative to brackets or sensor ports, mark it with a paint pen on the can and the pipe.

Hold point. The “before” pack (readings, photographs, identification) is saved in a folder with a name that includes the date and the DG set ID.

Leg 3: Remove the element and make the first seal

This leg is where most dust and most damage occur. Slow down.

Disconnect, label and set aside the ancillaries. Sensors, tapping lines, harnesses and heat shields are labelled before removal, with tags or tape and a photograph. Keep small parts in a labelled bag. Thread condition on sensor ports is worth checking as you go.

Loosen the device without shock. Use the correct tools and follow the supplier’s sequence. Do not strike clamps or the can with a hammer. A tap that frees a stubborn clamp can also send a shock into the ceramic.

Support the weight before the last fastener comes off. Two people, a lifting aid or a trolley, depending on weight. The element should never hang from its inlet flange alone.

Withdraw the element and cap both faces at once. The moment the element is clear, fit the rigid face caps. Tape them around the can. If the faces carry loose ash, avoid wiping them with a dry cloth, which spreads dust. Use a HEPA vacuum on the outside of the can only, and keep suction away from the face.

Do not rap, shake or blow out the element. Loose ash falls out with handling, and that is exactly what the cleaning contractor will deal with in a controlled cabinet. Our article on why compressed air may be unsuitable for some RECD filters explains why a quick blow-out on site is a poor idea.

Inspect and photograph both faces, then cap. Take pictures of both faces before the caps go on, with a scale. Look for cracks, gouges, glazed or melted areas and oily staining. If you see any of these, stop and send the pictures to the supplier before packing. A damaged element may be a reject for cleaning, as described in when a cleaning provider should reject an RECD filter.

Hold point. Both faces are capped, the exterior is vacuumed, and no loose ash is visible on the floor around the element.

Leg 4: The inner pack

The inner pack contains dust and protects the ceramic from moisture and light knocks.

  1. Wipe the can’s exterior with a damp cloth, working from top to bottom, then let it dry briefly. Dispose of the cloth with the other contaminated waste. See handling soot and ash removed during RECD servicing.
  2. Bag the element in the first heavy-duty bag, facing the neck away from the faces. Fold the neck and tape it twice.
  3. Wipe the first bag and put the element inside the second bag. Fold and tape again.
  4. Wrap the bagged element in foam or corrugated wrap, making sure the wrap does not cover the arrow markings.
  5. Place it in the inner box, which should be a snug fit. If there is a void, fill it with foam, not crumpled paper.
  6. Close and tape the inner box, and label the inlet and outlet directions on the outside.

Orientation. Keep the element upright and level as far as the design allows. A sloping or tipped element lets loose ash move toward one side, and rolling can scrape face caps loose. If the supplier gives an orientation instruction, follow it.

Hold point. Pick up the inner box and tilt it gently. Nothing inside should shift or rattle.

Leg 5: The outer crate

The outer shell takes the abuse. The inner box protects the element from the outer crate and the outer crate protects the inner box from the world.

  • Choose a crate with a floor, not a bare carton. A wooden crate or a strong double-wall carton on a pallet is typical.
  • Leave a cushioning gap on all sides and fill it with dense foam blocks or pulp that will not settle.
  • Keep the inner box off the floor of the crate on a cushion layer, so a drop does not transmit directly.
  • Close and strap the crate, with at least two straps in each direction on a carton.
  • Stick the “fragile, ceramic”, orientation and “this way up” labels on at least two faces and the top.
  • Weigh the packed crate and write the weight on the label. This helps the transport team plan their lift and gives you a second weighing for your records.

A shake test. With two people, lift one end an inch and set it down gently. Listen. Any thud from inside means a void. Reopen and fix it.

Hold point. The crate is closed, strapped, labelled and weighed, and passes the shake test.

Leg 6: Label and document

A package without paperwork has no history. Attach three things.

The tag sheet. A one-page tag that travels on the outside of the crate in a document pouch, with these fields:

FieldExample (illustrative)
Owner and siteExample Hospital, Plant Room 2
DG set and RECD IDDG-3, RECD serial XXXX
Element ID or batchAs marked on the can
Date and time packedDate, 14:20
Packed byName and phone number
Packed weight (kg)31.5
Inlet and outlet arrowsConfirmed on can and inner box
Condition at packing“No visible cracks. Light ash on inlet face. Photographs ref. 03”
Reason for service“ΔP at reference load 71 mbar, baseline 32 mbar”
Seal numbersA-10417, A-10418
Handling notes“Ceramic. Keep upright. Do not tip or stack”
Destination and receiver contactWorkshop name, receiving person
Return instructions“Return in same crate, sealed”

The custody sheet. A log of every handover, with date, time, name, signature and condition. At minimum: site to carrier, carrier to workshop, workshop to carrier on return, carrier to site.

The documents pouch. Put a copy of the order, the agreed scope and the photographs reference inside a pouch attached to the outside of the crate, not inside the sealed bags.

Hold point. The tag sheet and custody sheet are complete, and a photograph of the finished crate, with labels visible, is saved with the “before” pack.

Leg 7: Transport and receipt

Transport is the leg you control least, so control what you can.

The vehicle. An enclosed vehicle is better than an open pickup. The crate should be secured so that it cannot slide, tip or be crushed by other loads. Nothing heavy goes on top.

The driver. Brief the driver. Tell them the contents are fragile ceramic with fine dust, and ask them to avoid rough handling and to keep the crate upright.

Handover to the workshop. The workshop opens the crate in front of the driver, or at least with a photograph, and records the condition on the custody sheet: seals intact or not, outer crate damage, inner box damage, element condition at intake. Our guide to RECD delivery inspection offers a checklist you can adapt for the inbound side.

Receipt inspection. The workshop’s intake should include photographs of both faces, a weight as received and a flow or pressure test, as described in what an RECD cleaning report should show. Compare its weight with your packed weight less the packing; a large gap needs an explanation.

Hold point. The workshop has signed the custody sheet, and you have a copy.

Leg 8: Return inspection

The element comes back packed. Do not rush to refit it.

  1. Inspect the crate for damage and check the seal numbers against the sheet.
  2. Open it with a photographer present, and photograph each layer as you go.
  3. Check the faces against your “before” pictures for new cracks, chips, gouges or discolouration.
  4. Weigh the element if a scale is available. Compare with the provider’s after-weight.
  5. Read the provider’s report and apply the audit and arithmetic tests in verifying that the cleaning service was effective.
  6. Sign the return. If anything looks wrong, write it on the custody sheet before you sign, photograph it and notify the provider the same day.

For the checks before the set goes back into service, see quality checks before returning a generator to service after RECD cleaning.

Three illustrative failure stories

These are composites, not real cases.

The tipped crate. A team packs an element well but does not mark the crate. The driver lays it on its side so the load fits, a face cap loosens and ash spreads inside the bag. Nothing breaks, but the workshop’s intake photographs show dust on the outer bag and everyone has to explain it. A “this way up” label and strapping would have prevented it.

The helpful wipe-down. A technician wets a rag and wipes the can, and water runs into an uncapped face. The element goes into the bag damp, and the workshop finds the intake weight higher than the packed weight. The job stalls while the element dries. Keep faces capped, and use damp cloths on the exterior only.

The missing “before”. An element arrives with a hairline crack. The site has no face photographs from before removal, the workshop took none at intake and the carrier says the crate looked fine. Nobody can say when the crack appeared, so the cost is argued over and never settled.

Packing cost versus damage cost

A short sum shows why careful packing is cheap. The figures are assumptions for illustration, not quotations.

ItemCost (₹, illustrative)
Packing materials: caps, bags, foam, crate, seals3,500
Extra labour for careful packing and photography (two people, one hour)1,200
Total cost of careful packing4,700
Replacement element if cracked in transit1,20,000
Cost of a repeat service visit and temporary cover (one week)60,000
Total cost of one transit failure1,80,000

Careful packing costs about 2.6% of one failure (4,700 ÷ 1,80,000 = 0.026). If careful packing reduces the chance of a failure on any one trip by just a few percentage points, it pays for itself. And that comparison ignores the argument.

If you ship several elements a year, build the packing materials into a reusable kit, and keep it with the asset records described in the RECD asset register for a multi-site DG fleet.

What not to pack inside

Leave out sensors and wiring (unless the provider asks), loose gaskets, tools or bolts that could scratch the ceramic, any catalyst section the provider has not agreed to take, and paperwork inside the sealed bags. Order new gaskets from your spare parts list instead of shipping the old ones.

A pre-dispatch checklist

Use this list at the final hold point.

  • [ ] Written scope, responsibility for transit damage and return terms agreed
  • [ ] DG set isolated, locked out and cooled before work
  • [ ] “Before” readings, photographs and identification saved
  • [ ] Flow arrow and clocking marked on can and pipe
  • [ ] Ancillaries labelled and stored
  • [ ] Both faces photographed, then capped with rigid caps
  • [ ] Exterior vacuumed and wiped, waste bagged
  • [ ] Double-bagged, foam-wrapped, in snug inner box
  • [ ] Outer crate with cushioning gap, strapped, shake-tested
  • [ ] Labels: fragile, ceramic, this way up, inlet and outlet
  • [ ] Tag sheet and custody sheet completed, tamper seals numbered
  • [ ] Packed weight recorded and photograph of finished crate saved
  • [ ] Driver briefed, vehicle suitable, receiver contact confirmed
  • [ ] Cover arrangement in place for the DG set while the element is away

Frequently asked questions

Can I send the whole RECD instead of only the filter element?

Only if the provider agrees and the supplier’s procedure allows it. Sending the whole body is heavier, riskier and may attract extra charges for removing parts the cleaning does not need. Agree the scope in writing first.

Is it acceptable to clean the loose ash off before packing?

Surface vacuuming of the exterior is fine. Blowing out, tapping or shaking the element to “make it lighter” is not, because it spreads dust and can damage the ceramic. Leave ash removal to the cleaning provider’s controlled process.

How should I handle the ash that falls off during packing?

Treat it as waste that needs containment and a defined route. Collect it with a HEPA vacuum or damp cloths, bag it and label the bag. See the article on handling soot and ash removed during RECD servicing, and follow your State Pollution Control Board’s requirements for the waste.

Who is responsible if the element breaks in transit?

It depends on your agreement. A US truck-maker bulletin cited above puts shipping damage on the party sending the filter, but your own contract may differ. Settle it in writing, and use the tag sheet, photographs and receipt inspection to document condition at each handover.

Do I need to regenerate the filter before sending it?

Usually not. Regeneration burns soot but not ash, and the cleaning provider will treat remaining soot in its own process. Follow the supplier’s instruction, and see RECD regeneration vs filter cleaning if you are unsure which service you need.

The short version

Treat the journey of an ash-loaded RECD filter as a custody route with eight legs: plan, isolate, capture the “before” state, remove and cap, inner-pack, crate, document, hand over and inspect on return. Pack as if the element will be dropped once, because sometimes it is. Photograph at every handover, and agree who owns the risk before the element moves.

If you would like help planning the removal and logistics for your own DG set, browse our retrofit emission control devices, read our FAQ or contact the Aceget team.

Keep reading



2 Comments

Leave a Reply