Short answer: usually, no. In most cleaning methods the sensors come off before the filter does, and the reasons are practical, not fussy. Sensors are fragile, they sit in hot, sooty, ash-laden places, and the cleaning methods that restore a filter (heat, water, vibration, high-pressure air) are the same ones that can damage a sensor or push debris into its sensing line.
But “usually” hides useful detail. Some sensors are part of the filter housing and are not touched by the cleaning at all. Some cleaning methods never reach the sensor. Some sensors can stay if you protect them, and some must never be left on. The right answer depends on the component, the method and the manufacturer’s instruction.
This guide gives a component-by-component map of what stays and what comes off, a method-by-method matrix showing how each cleaning route treats a sensor, a tagging and port-care routine for removal, a refit and zero check and a worked example of why ten minutes of removal can be cheaper than a risky shortcut. As always, your device manufacturer’s service instruction governs. What follows is a practical frame for the conversation with the cleaning provider.
Which sensors are we talking about?
An RECD installation may include several, depending on the model.
| Sensor | What it does | Where it sits |
|---|---|---|
| Differential pressure sensor (or pressure switch) | Measures the pressure drop across the filter | Body on a bracket, with two sensing tubes to the pipe or housing ahead of and behind the element |
| Inlet temperature sensor | Reads exhaust temperature entering the filter | In a port or bung on the inlet pipe or housing |
| Outlet temperature sensor | Reads temperature after the element | In a port on the outlet side |
| Mid-bed temperature sensor | Reads temperature within or between elements (where fitted) | In a port in the housing |
| Controller harness and connectors | Carry signals and heater power | Run along the device |
| Heater element (if fitted) | Part of an active regeneration system | Within the inlet section |
Our articles on temperature sensor placement and pressure sensors versus pressure switches explain the monitoring side. This guide is about what happens to them when the filter is serviced.
What manufacturers and workshops say
Service manuals in the diesel world are consistent on the sequence. A Kubota workshop procedure for removing a diesel particulate filter directs the technician to disconnect the differential pressure sensor, its tubes and the temperature sensors before removing the filter assembly. Independent repair guidance describes spraying penetrating oil on seized temperature sensors, then inspecting the threads of the sensor ports for damage. Another manufacturer’s instructions ask the technician to note the installed position of components before removal, so that they go back in the same place. A radiator-repair article on exhaust gas temperature sensors makes the further point that the threaded bung can itself be damaged by overtightening or cross-threading and should be checked at refit.
None of this is about RECDs on DG sets specifically, but the physics is the same, and a provider who removes sensors by default is following standard practice.
Why sensors come off
Five reasons, each tied to something that can go wrong.
- Heat. Thermal cleaning ovens and “bake and blow” routes take the element to high temperatures. A sensor’s body, cable insulation and connector have temperature limits, and the oven set point may exceed them.
- Water and chemicals. Aqueous or ultrasonic cleaning wets the element and its surroundings. A pressure sensor’s electronics and a connector are not intended for immersion or spray.
- Pressure and shock. Compressed-air blowing, flushing and handling put sudden pressure on sensing ports, which can force soot or water into a sensing tube or strain a diaphragm.
- Blocked lines. Soot or ash pushed into the pressure tubes gives wrong readings later. Our article on separating a sensor fault from an RECD performance problem explains how clogged lines can mimic a bad sensor.
- Access. The sensor ports can obstruct the housing during handling, or the filter cannot be lifted out of the shell with the harness attached.
There is also a sixth, quieter reason: inspection. Removing the sensor lets you see its tip, check the port threads and confirm that the port itself is clear.
The component-by-component map
| Component | During removal of the element | During cleaning (off-site) | During cleaning (on-site, element in place) | Notes |
|---|---|---|---|---|
| Differential pressure sensor body | Comes off or stays on its bracket, disconnected and protected | Stays at site | Protect from spray and blow-back | Do not send with the element |
| Pressure sensing tubes | Disconnect both ends, cap them | Stay at site, inspect and blow through | Cap before any wet or air cleaning | Check for kinks, soot and water |
| Pressure tapping points on the housing | Inspect, clear | Cleaned with the housing if sent | Clear carefully; avoid pushing debris in | Fit port plugs during cleaning |
| Inlet and outlet temperature sensors | Come out of their ports | Stay at site, tagged | Come out if the method uses heat or water | Inspect tip and threads |
| Mid-bed sensor | Comes out | Stays at site | Comes out | Often hard to reach; allow time |
| Harness and connectors | Disconnect and bag the connector ends | Stay at site | Cover | Protect from dust and water |
| Heater and its power wiring | Isolate power first; disconnect | Stays with the housing or element per design | Disconnect | Follow the manufacturer’s isolation steps |
| Controller | Stays on its mount | Stays | Stays, covered | Never subject it to a cleaning process |
| Sensor port bungs | Inspect threads | Inspect | Inspect | Replace damaged bungs |
The table above is a typical pattern. Some designs integrate a sensor into a part that does travel with the filter, in which case the provider needs the manufacturer’s guidance on how that part may be treated.
The method-by-method matrix
Different cleaning methods put different demands on a sensor. The principle is: the more severe the method, the more firmly the sensors should be removed.
| Method | What happens to the filter | Risk to sensors left on | Typical practice |
|---|---|---|---|
| Compressed-air blow (with vacuum extraction) | Air pulsed through the channels, ash extracted | Back-blown soot into sensing lines; shock to the diaphragm | Remove or disconnect and cap |
| Thermal (bake and blow) | Element heated in an oven to burn off soot, then air-blown | Sensor and cable melt or degrade at oven temperature | Always remove |
| Aqueous (water-based flushing) | Element flushed or soaked | Water ingress to sensor and connector; corrosion | Remove |
| Ultrasonic | Element immersed in a bath with ultrasonic agitation | Immersion damage; vibration | Remove |
| On-site vacuum and brush (light ash) | Surface ash removed in place | Dust in ports; low direct risk | Cap ports; sensors may stay if shielded, if the maker allows |
| Regeneration (not cleaning) | Engine-driven soot burn-off | None; sensors are designed for this | Sensors stay, since regeneration is a normal operating mode |
That last row is a useful reminder. Regeneration and cleaning are different things, and sensors are designed for the first. We explain the difference in RECD regeneration versus filter cleaning, and the choice of route in on-site versus off-site RECD filter cleaning. For how each method works and what questions to ask, see thermal cleaning of RECD filters and ultrasonic cleaning claims and evidence.
When might sensors safely stay?
There are cases, and it pays to be explicit about the conditions.
| Condition | Why it might be acceptable |
|---|---|
| The method is dry and low-energy (light vacuum, brush) | No heat, water or shock reaches the sensor |
| The sensing ports and tubes are capped and the sensor body is shielded | Contamination cannot enter |
| The manufacturer’s instruction allows it | The maker has tested the design |
| The sensor is integral to a housing that is not being cleaned | Not exposed |
| The scope was agreed in writing | Responsibility is clear |
If a provider proposes leaving sensors on for a thermal, aqueous or ultrasonic job, ask for the manufacturer’s written approval and the sensor’s rated temperature and ingress rating. If neither exists, take the sensors off.
What to do at removal
A disciplined removal takes a few minutes per sensor and saves hours later. The steps:
- Photograph the installed state. Show each sensor, its port, its cable route and its connector, with a label.
- Tag every sensor and connector with a matching ID, so that a temperature sensor from the inlet cannot be refitted on the outlet. (See the tag sheet below.)
- Isolate power and let the unit cool. Never pull a hot sensor, and follow the heater isolation steps first.
- Free seized sensors carefully. Penetrating oil and patience, not heat and force. A damaged port thread costs more than a new sensor.
- Disconnect pressure tubes at both ends and cap them. Note which tube went to which port. Inlet and outlet tubes swapped at refit give a negative or meaningless reading.
- Inspect each sensor tip. Heavy soot is expected. Cracks, bent probes or a damaged seal are not.
- Inspect the port thread and the bung. Clean the thread with a suitable tool and replace a damaged bung.
- Plug the open ports. An open port lets debris into the exhaust path.
- Bag and label the sensors, and store them at site, not with the filter.
- Record all of it. Our RECD event log guide shows where.
A tag sheet
| Tag | Sensor | Port position | Connector | Cable route | Torque (from manufacturer) | Condition on removal |
|---|---|---|---|---|---|---|
| S1 | Inlet temperature | Inlet pipe, upstream face | C1, 2-pin | Along left bracket | [value] | Tip sooted, no damage |
| S2 | Outlet temperature | Outlet cone | C2, 2-pin | Along left bracket | [value] | Tip sooted, no damage |
| S3 | Differential pressure | Bracket on frame | C3, 3-pin | Behind heat shield | n/a | Body clean |
| T1 | Pressure tube, inlet side | Inlet port P1 | n/a | Clip positions 1, 2 | n/a | Slight soot inside |
| T2 | Pressure tube, outlet side | Outlet port P2 | n/a | Clip positions 1, 2 | n/a | Clear |
Use the manufacturer’s torque value for each sensor. Over-torquing breaks the sensor or the port, and under-torquing leaks.
Port and line care
Ports and lines get less attention than sensors, and cause many of the faults that follow a cleaning.
- Check the port thread for stripping, cross-threading marks and carbon build-up. A thread that does not accept the sensor cleanly will leak at temperature.
- Use the right anti-seize only where the manufacturer specifies it, because some compounds affect sensor readings or burn off.
- Blow through pressure lines with gentle, dry air (disconnected from the sensor) to clear soot and moisture, and look for kinks and cracks.
- Replace brittle or cracked tube and clips. Tubes near a hot exhaust age.
- Keep the tube lengths and routing as originally installed. Sagging lines collect condensate and give erratic readings.
- Check the sensor’s seal or washer. Many are single-use.
If you do not hold a spare for a damaged part, see specifying replacement RECD sensors for compatibility and RECD spare parts: what to request.
A worked example: is removal worth the time?
The numbers are illustrative. A site cleans an element off-site using a thermal method. There are three sensors on the unit: two temperature sensors at ₹3,500 each and one differential pressure sensor at ₹8,000, with a technician cost of ₹600 per hour.
Removal and refit, done properly
- Time: about 40 minutes to tag, remove, cap, inspect and later refit three sensors and two tubes, plus 20 minutes for the post-refit check. Total 60 minutes = ₹600.
Leaving the sensors on, thermal job
Assume, purely for illustration, that the oven reaches a temperature above the sensors’ ratings in 6 out of 10 such jobs and that a damaged sensor must be replaced. Expected replacement spend per job: 0.6 × (3,500 + 3,500 + 8,000) = 0.6 × 15,000 = ₹9,000. There are also hidden costs: a wrong reading after refit, a troubleshooting call-out and time with the set down.
| Remove and refit | Leave on | |
|---|---|---|
| Direct cost per job | ₹600 | ₹9,000 expected |
| Risk of wrong readings after refit | Low, with zero check | Higher |
| Evidence of sensor condition | Photos and tag sheet | None |
Reading it. The point is not the precise failure rate, which is assumed here. It is that removal costs less than one wrong guess, and gives an inspection record as a by-product. Where the maker approves leaving sensors on for a dry, low-energy method, the saving is real, but it should be a decision, not a default.
Refit and the zero check
Refit is where sensor faults are created. Follow the tag sheet in reverse.
- Refit the element first, in the correct flow direction, then the sensors. Our return-to-service quality checks cover the element side.
- Fit each sensor in the port on its tag, with a new seal where required, to the specified torque.
- Reconnect the harness along its original route, away from hot surfaces. See cable routing near hot exhaust lines.
- Reconnect the pressure tubes inlet to inlet and outlet to outlet, with clips in place and no kinks.
- Power up the controller with the engine off. Check that no sensor fault codes are present.
- Zero check on the pressure sensor. With the engine stopped and both ports open to atmosphere (or as the manufacturer directs), the differential reading should be at or very near zero. Note the figure. A large offset points to a faulty sensor, a blocked or swapped line or a wiring issue.
- Temperature sanity check. With the engine cold, the temperature sensors should read close to ambient and close to each other. A sensor reading far from the others is suspect, or it is on the wrong port.
- Start and run at the reference load, then compare the pressure drop with the clean-state baseline. A reading above baseline after a good cleaning points to partial blockage, a refit problem or a line fault. Our article on what to do when pressure stays high after a cleaning walks through the diagnosis.
- Record everything in the event log and the cleaning file, and keep the tag sheet.
Our guide to installed RECD sensor calibration and documentation says what to keep for the sensors themselves.
Special cases worth a conversation
- Sensors that will not come out. A seized temperature sensor may snap if forced. Stop, apply penetrating oil, wait and try again. If it still will not move, tell the provider and the manufacturer. A broken sensor stub in a port is a repair job, and it is better found before the element is dispatched than after.
- Integrated sensor-and-gasket assemblies. Some designs combine a sensor with a flange or a spacer. The assembly may have to be treated as a unit, and the maker’s instruction says how.
- Older installations with no documentation. If nobody knows which tube goes where, take photographs and label before touching anything, then draw the layout. It is the same work you would do at a later fault, done while the unit is open.
- Fleet of identical units. Sensors from different sets look the same and are easily mixed. Mark the unit number on each bag and tag, so that a sensor from set 4 does not end up on set 7.
- Heater-equipped systems. Isolate and lock out the heater supply before anything else, and confirm with a meter that it is dead.
What to put in the cleaning scope
Agree who handles the sensors before the job starts, and write it into the order.
| Item | Suggested wording |
|---|---|
| Sensor removal | “Provider/owner removes, tags and stores all temperature and pressure sensors before dispatch.” |
| Tubes and harness | “Pressure tubes capped at both ends; harness connectors bagged.” |
| Ports | “Ports plugged; threads inspected and condition recorded.” |
| Heater | “Power isolated per manufacturer’s instruction before removal.” |
| Refit | “Owner or authorised technician refits sensors per tag sheet and performs zero and temperature checks.” |
| Liability | “Provider is responsible for sensors only where they are in its custody.” |
If sensors travel with the element, the quote should say who is liable for them and how they will be packed. Our guide to what an RECD cleaning quote should include shows where this sits, and the packing guide shows how to keep a sensor from rattling in a box.
Mistakes to avoid
- Leaving sensors on for a thermal or wet process without written approval.
- Sending sensors off with the element where they can be lost or damaged.
- Swapping inlet and outlet tubes at refit.
- Refitting a sensor in the wrong port.
- Cross-threading or over-torquing into a clean but fragile port.
- Skipping the zero check and assuming the first reading is true.
- Blaming the filter when a blocked sensing line is the real fault.
- Forgetting to plug open ports during the job.
Frequently asked questions
Can I leave the sensors on when the filter is cleaned?
For dry, low-energy cleaning with ports capped and the maker’s approval, sometimes. For thermal, aqueous or ultrasonic cleaning, the sensors should come off.
Do I need to remove the temperature sensors too?
Generally yes, particularly for thermal methods, because oven temperatures can exceed a sensor’s rating, and removal lets you inspect the port threads.
What happens if I mix up the pressure tubes?
The reading can be negative, zero or wrong. Tag the tubes and ports and reconnect them in the same positions.
Is a zero check really necessary?
Yes. It takes minutes and catches blocked lines, swapped tubes and sensor offset before they are mistaken for a filter problem.
Does regeneration need the sensors removed?
No. Regeneration is a normal operating mode and the sensors are built for it. Only cleaning, where the element comes out or is treated, calls for removal.
Who should remove the sensors, the owner or the provider?
Either, as long as the order says so. Many owners remove and refit with their own technician and send only the element, which keeps the sensors at site.
Closing thought
In most cases the sensors come off, because the cleaning methods that restore a filter are hard on a sensor. Use the component map to decide what stays and the method matrix to decide how strict to be. Tag every sensor, cap every tube, inspect every port and keep the sensors at site. After refit, run the zero and temperature checks before you trust any reading. And write the scope into the order, so that nobody has to guess.
If you need help with sensor specification, spare stock or a cleaning scope, browse our retrofit emission control devices, read our DG set emission regulations guide or contact the Aceget team.