Can an RECD Filter Be Cleaned Without Removing Its Sensors?

Short answer: usually, no. In most cleaning methods the sensors come off before the filter does, and the reasons are practical, not fussy. Sensors are fragile, they sit in hot, sooty, ash-laden places, and the cleaning methods that restore a filter (heat, water, vibration, high-pressure air) are the same ones that can damage a sensor or push debris into its sensing line.

But “usually” hides useful detail. Some sensors are part of the filter housing and are not touched by the cleaning at all. Some cleaning methods never reach the sensor. Some sensors can stay if you protect them, and some must never be left on. The right answer depends on the component, the method and the manufacturer’s instruction.

This guide gives a component-by-component map of what stays and what comes off, a method-by-method matrix showing how each cleaning route treats a sensor, a tagging and port-care routine for removal, a refit and zero check and a worked example of why ten minutes of removal can be cheaper than a risky shortcut. As always, your device manufacturer’s service instruction governs. What follows is a practical frame for the conversation with the cleaning provider.

Which sensors are we talking about?

An RECD installation may include several, depending on the model.

SensorWhat it doesWhere it sits
Differential pressure sensor (or pressure switch)Measures the pressure drop across the filterBody on a bracket, with two sensing tubes to the pipe or housing ahead of and behind the element
Inlet temperature sensorReads exhaust temperature entering the filterIn a port or bung on the inlet pipe or housing
Outlet temperature sensorReads temperature after the elementIn a port on the outlet side
Mid-bed temperature sensorReads temperature within or between elements (where fitted)In a port in the housing
Controller harness and connectorsCarry signals and heater powerRun along the device
Heater element (if fitted)Part of an active regeneration systemWithin the inlet section

Our articles on temperature sensor placement and pressure sensors versus pressure switches explain the monitoring side. This guide is about what happens to them when the filter is serviced.

What manufacturers and workshops say

Service manuals in the diesel world are consistent on the sequence. A Kubota workshop procedure for removing a diesel particulate filter directs the technician to disconnect the differential pressure sensor, its tubes and the temperature sensors before removing the filter assembly. Independent repair guidance describes spraying penetrating oil on seized temperature sensors, then inspecting the threads of the sensor ports for damage. Another manufacturer’s instructions ask the technician to note the installed position of components before removal, so that they go back in the same place. A radiator-repair article on exhaust gas temperature sensors makes the further point that the threaded bung can itself be damaged by overtightening or cross-threading and should be checked at refit.

None of this is about RECDs on DG sets specifically, but the physics is the same, and a provider who removes sensors by default is following standard practice.

Why sensors come off

Five reasons, each tied to something that can go wrong.

  1. Heat. Thermal cleaning ovens and “bake and blow” routes take the element to high temperatures. A sensor’s body, cable insulation and connector have temperature limits, and the oven set point may exceed them.
  2. Water and chemicals. Aqueous or ultrasonic cleaning wets the element and its surroundings. A pressure sensor’s electronics and a connector are not intended for immersion or spray.
  3. Pressure and shock. Compressed-air blowing, flushing and handling put sudden pressure on sensing ports, which can force soot or water into a sensing tube or strain a diaphragm.
  4. Blocked lines. Soot or ash pushed into the pressure tubes gives wrong readings later. Our article on separating a sensor fault from an RECD performance problem explains how clogged lines can mimic a bad sensor.
  5. Access. The sensor ports can obstruct the housing during handling, or the filter cannot be lifted out of the shell with the harness attached.

There is also a sixth, quieter reason: inspection. Removing the sensor lets you see its tip, check the port threads and confirm that the port itself is clear.

The component-by-component map

ComponentDuring removal of the elementDuring cleaning (off-site)During cleaning (on-site, element in place)Notes
Differential pressure sensor bodyComes off or stays on its bracket, disconnected and protectedStays at siteProtect from spray and blow-backDo not send with the element
Pressure sensing tubesDisconnect both ends, cap themStay at site, inspect and blow throughCap before any wet or air cleaningCheck for kinks, soot and water
Pressure tapping points on the housingInspect, clearCleaned with the housing if sentClear carefully; avoid pushing debris inFit port plugs during cleaning
Inlet and outlet temperature sensorsCome out of their portsStay at site, taggedCome out if the method uses heat or waterInspect tip and threads
Mid-bed sensorComes outStays at siteComes outOften hard to reach; allow time
Harness and connectorsDisconnect and bag the connector endsStay at siteCoverProtect from dust and water
Heater and its power wiringIsolate power first; disconnectStays with the housing or element per designDisconnectFollow the manufacturer’s isolation steps
ControllerStays on its mountStaysStays, coveredNever subject it to a cleaning process
Sensor port bungsInspect threadsInspectInspectReplace damaged bungs

The table above is a typical pattern. Some designs integrate a sensor into a part that does travel with the filter, in which case the provider needs the manufacturer’s guidance on how that part may be treated.

The method-by-method matrix

Different cleaning methods put different demands on a sensor. The principle is: the more severe the method, the more firmly the sensors should be removed.

MethodWhat happens to the filterRisk to sensors left onTypical practice
Compressed-air blow (with vacuum extraction)Air pulsed through the channels, ash extractedBack-blown soot into sensing lines; shock to the diaphragmRemove or disconnect and cap
Thermal (bake and blow)Element heated in an oven to burn off soot, then air-blownSensor and cable melt or degrade at oven temperatureAlways remove
Aqueous (water-based flushing)Element flushed or soakedWater ingress to sensor and connector; corrosionRemove
UltrasonicElement immersed in a bath with ultrasonic agitationImmersion damage; vibrationRemove
On-site vacuum and brush (light ash)Surface ash removed in placeDust in ports; low direct riskCap ports; sensors may stay if shielded, if the maker allows
Regeneration (not cleaning)Engine-driven soot burn-offNone; sensors are designed for thisSensors stay, since regeneration is a normal operating mode

That last row is a useful reminder. Regeneration and cleaning are different things, and sensors are designed for the first. We explain the difference in RECD regeneration versus filter cleaning, and the choice of route in on-site versus off-site RECD filter cleaning. For how each method works and what questions to ask, see thermal cleaning of RECD filters and ultrasonic cleaning claims and evidence.

When might sensors safely stay?

There are cases, and it pays to be explicit about the conditions.

ConditionWhy it might be acceptable
The method is dry and low-energy (light vacuum, brush)No heat, water or shock reaches the sensor
The sensing ports and tubes are capped and the sensor body is shieldedContamination cannot enter
The manufacturer’s instruction allows itThe maker has tested the design
The sensor is integral to a housing that is not being cleanedNot exposed
The scope was agreed in writingResponsibility is clear

If a provider proposes leaving sensors on for a thermal, aqueous or ultrasonic job, ask for the manufacturer’s written approval and the sensor’s rated temperature and ingress rating. If neither exists, take the sensors off.

What to do at removal

A disciplined removal takes a few minutes per sensor and saves hours later. The steps:

  1. Photograph the installed state. Show each sensor, its port, its cable route and its connector, with a label.
  2. Tag every sensor and connector with a matching ID, so that a temperature sensor from the inlet cannot be refitted on the outlet. (See the tag sheet below.)
  3. Isolate power and let the unit cool. Never pull a hot sensor, and follow the heater isolation steps first.
  4. Free seized sensors carefully. Penetrating oil and patience, not heat and force. A damaged port thread costs more than a new sensor.
  5. Disconnect pressure tubes at both ends and cap them. Note which tube went to which port. Inlet and outlet tubes swapped at refit give a negative or meaningless reading.
  6. Inspect each sensor tip. Heavy soot is expected. Cracks, bent probes or a damaged seal are not.
  7. Inspect the port thread and the bung. Clean the thread with a suitable tool and replace a damaged bung.
  8. Plug the open ports. An open port lets debris into the exhaust path.
  9. Bag and label the sensors, and store them at site, not with the filter.
  10. Record all of it. Our RECD event log guide shows where.

A tag sheet

TagSensorPort positionConnectorCable routeTorque (from manufacturer)Condition on removal
S1Inlet temperatureInlet pipe, upstream faceC1, 2-pinAlong left bracket[value]Tip sooted, no damage
S2Outlet temperatureOutlet coneC2, 2-pinAlong left bracket[value]Tip sooted, no damage
S3Differential pressureBracket on frameC3, 3-pinBehind heat shieldn/aBody clean
T1Pressure tube, inlet sideInlet port P1n/aClip positions 1, 2n/aSlight soot inside
T2Pressure tube, outlet sideOutlet port P2n/aClip positions 1, 2n/aClear

Use the manufacturer’s torque value for each sensor. Over-torquing breaks the sensor or the port, and under-torquing leaks.

Port and line care

Ports and lines get less attention than sensors, and cause many of the faults that follow a cleaning.

  • Check the port thread for stripping, cross-threading marks and carbon build-up. A thread that does not accept the sensor cleanly will leak at temperature.
  • Use the right anti-seize only where the manufacturer specifies it, because some compounds affect sensor readings or burn off.
  • Blow through pressure lines with gentle, dry air (disconnected from the sensor) to clear soot and moisture, and look for kinks and cracks.
  • Replace brittle or cracked tube and clips. Tubes near a hot exhaust age.
  • Keep the tube lengths and routing as originally installed. Sagging lines collect condensate and give erratic readings.
  • Check the sensor’s seal or washer. Many are single-use.

If you do not hold a spare for a damaged part, see specifying replacement RECD sensors for compatibility and RECD spare parts: what to request.

A worked example: is removal worth the time?

The numbers are illustrative. A site cleans an element off-site using a thermal method. There are three sensors on the unit: two temperature sensors at ₹3,500 each and one differential pressure sensor at ₹8,000, with a technician cost of ₹600 per hour.

Removal and refit, done properly

  • Time: about 40 minutes to tag, remove, cap, inspect and later refit three sensors and two tubes, plus 20 minutes for the post-refit check. Total 60 minutes = ₹600.

Leaving the sensors on, thermal job

Assume, purely for illustration, that the oven reaches a temperature above the sensors’ ratings in 6 out of 10 such jobs and that a damaged sensor must be replaced. Expected replacement spend per job: 0.6 × (3,500 + 3,500 + 8,000) = 0.6 × 15,000 = ₹9,000. There are also hidden costs: a wrong reading after refit, a troubleshooting call-out and time with the set down.

Remove and refitLeave on
Direct cost per job₹600₹9,000 expected
Risk of wrong readings after refitLow, with zero checkHigher
Evidence of sensor conditionPhotos and tag sheetNone

Reading it. The point is not the precise failure rate, which is assumed here. It is that removal costs less than one wrong guess, and gives an inspection record as a by-product. Where the maker approves leaving sensors on for a dry, low-energy method, the saving is real, but it should be a decision, not a default.

Refit and the zero check

Refit is where sensor faults are created. Follow the tag sheet in reverse.

  1. Refit the element first, in the correct flow direction, then the sensors. Our return-to-service quality checks cover the element side.
  2. Fit each sensor in the port on its tag, with a new seal where required, to the specified torque.
  3. Reconnect the harness along its original route, away from hot surfaces. See cable routing near hot exhaust lines.
  4. Reconnect the pressure tubes inlet to inlet and outlet to outlet, with clips in place and no kinks.
  5. Power up the controller with the engine off. Check that no sensor fault codes are present.
  6. Zero check on the pressure sensor. With the engine stopped and both ports open to atmosphere (or as the manufacturer directs), the differential reading should be at or very near zero. Note the figure. A large offset points to a faulty sensor, a blocked or swapped line or a wiring issue.
  7. Temperature sanity check. With the engine cold, the temperature sensors should read close to ambient and close to each other. A sensor reading far from the others is suspect, or it is on the wrong port.
  8. Start and run at the reference load, then compare the pressure drop with the clean-state baseline. A reading above baseline after a good cleaning points to partial blockage, a refit problem or a line fault. Our article on what to do when pressure stays high after a cleaning walks through the diagnosis.
  9. Record everything in the event log and the cleaning file, and keep the tag sheet.

Our guide to installed RECD sensor calibration and documentation says what to keep for the sensors themselves.

Special cases worth a conversation

  • Sensors that will not come out. A seized temperature sensor may snap if forced. Stop, apply penetrating oil, wait and try again. If it still will not move, tell the provider and the manufacturer. A broken sensor stub in a port is a repair job, and it is better found before the element is dispatched than after.
  • Integrated sensor-and-gasket assemblies. Some designs combine a sensor with a flange or a spacer. The assembly may have to be treated as a unit, and the maker’s instruction says how.
  • Older installations with no documentation. If nobody knows which tube goes where, take photographs and label before touching anything, then draw the layout. It is the same work you would do at a later fault, done while the unit is open.
  • Fleet of identical units. Sensors from different sets look the same and are easily mixed. Mark the unit number on each bag and tag, so that a sensor from set 4 does not end up on set 7.
  • Heater-equipped systems. Isolate and lock out the heater supply before anything else, and confirm with a meter that it is dead.

What to put in the cleaning scope

Agree who handles the sensors before the job starts, and write it into the order.

ItemSuggested wording
Sensor removal“Provider/owner removes, tags and stores all temperature and pressure sensors before dispatch.”
Tubes and harness“Pressure tubes capped at both ends; harness connectors bagged.”
Ports“Ports plugged; threads inspected and condition recorded.”
Heater“Power isolated per manufacturer’s instruction before removal.”
Refit“Owner or authorised technician refits sensors per tag sheet and performs zero and temperature checks.”
Liability“Provider is responsible for sensors only where they are in its custody.”

If sensors travel with the element, the quote should say who is liable for them and how they will be packed. Our guide to what an RECD cleaning quote should include shows where this sits, and the packing guide shows how to keep a sensor from rattling in a box.

Mistakes to avoid

  • Leaving sensors on for a thermal or wet process without written approval.
  • Sending sensors off with the element where they can be lost or damaged.
  • Swapping inlet and outlet tubes at refit.
  • Refitting a sensor in the wrong port.
  • Cross-threading or over-torquing into a clean but fragile port.
  • Skipping the zero check and assuming the first reading is true.
  • Blaming the filter when a blocked sensing line is the real fault.
  • Forgetting to plug open ports during the job.

Frequently asked questions

Can I leave the sensors on when the filter is cleaned?

For dry, low-energy cleaning with ports capped and the maker’s approval, sometimes. For thermal, aqueous or ultrasonic cleaning, the sensors should come off.

Do I need to remove the temperature sensors too?

Generally yes, particularly for thermal methods, because oven temperatures can exceed a sensor’s rating, and removal lets you inspect the port threads.

What happens if I mix up the pressure tubes?

The reading can be negative, zero or wrong. Tag the tubes and ports and reconnect them in the same positions.

Is a zero check really necessary?

Yes. It takes minutes and catches blocked lines, swapped tubes and sensor offset before they are mistaken for a filter problem.

Does regeneration need the sensors removed?

No. Regeneration is a normal operating mode and the sensors are built for it. Only cleaning, where the element comes out or is treated, calls for removal.

Who should remove the sensors, the owner or the provider?

Either, as long as the order says so. Many owners remove and refit with their own technician and send only the element, which keeps the sensors at site.

Closing thought

In most cases the sensors come off, because the cleaning methods that restore a filter are hard on a sensor. Use the component map to decide what stays and the method matrix to decide how strict to be. Tag every sensor, cap every tube, inspect every port and keep the sensors at site. After refit, run the zero and temperature checks before you trust any reading. And write the scope into the order, so that nobody has to guess.

If you need help with sensor specification, spare stock or a cleaning scope, browse our retrofit emission control devices, read our DG set emission regulations guide or contact the Aceget team.