Somewhere on the technical offer, in a line between the filter volume and the catalyst loading, there is a figure such as “200 CPSI”. Buyers tend to treat it as a quality score: a bigger number must mean a finer, better filter, and a smaller one a cheaper compromise. It is neither. CPSI describes a geometry, and geometry creates trade-offs. The same number can sit in an excellent filter or an ill-suited one, depending on what is printed beside it. This guide to RECD filter cell density CPSI shows buyers what the number does and does not tell them.
This article explains what cell density means for a buyer of a retrofit emission control device (RECD). We define the term and its companion figure, wall thickness, then work through a small table of real geometry arithmetic so you can see how the numbers behave. We follow with the six things cell density moves, five myths, a five-number specification line to demand from every supplier and a worked comparison of two quotations. The geometry figures here are calculated from simple square-cell formulas and are for explanation. Porosity, pore size, ash, soot layers and the maker’s design all change real performance, so the supplier’s data for your core takes priority.
What CPSI is, and what it is not
CPSI stands for cells per square inch. Picture the flat end of the filter core. It is a grid of small square channels, and CPSI counts how many channels fit in one square inch of that face. A core quoted at 200 CPSI has roughly two hundred channels in each square inch. Many datasheets pair the figure with wall thickness in mils (thousandths of an inch) and write it as “200/12”, meaning 200 cells per square inch and walls 12 mils thick. Patents on thin-wall filters describe cell densities between 100 and 350 CPSI and compare walls of 12 to 18 mils in earlier designs with thinner walls of under 11 mils (US 8814974).
Three clarifications prevent common misreadings.
- CPSI counts all the channels, but only half are inlet channels. In a wall-flow filter, alternate cells are blocked at opposite ends. Half are open at the inlet face and half at the outlet face. The “open area” that the gas first meets is therefore about half of the total open area.
- CPSI is not a measure of filtering fineness. Particles are stopped by the pores in the wall, not by the size of the channels. Our next article, why RECD filter porosity cannot be judged from appearance, covers the wall.
- CPSI does not stand alone. The figure only makes sense with wall thickness, material, core size and plugging pattern. Two offers at “200 CPSI” can be quite different filters.
Geometry arithmetic you can check yourself
For square cells, the geometry follows from two inputs. The distance between channel centres (the pitch) is one divided by the square root of CPSI, in inches. The open channel width is the pitch minus the wall thickness. From those two, the open fraction and the wall area per unit volume follow directly.
The table below applies the arithmetic to five common-style combinations. It adds three scaling indices, all set to 1.00 for the 200/12 core so that the other rows read as multiples. The indices are simplified models for illustration: the filtration area index is the area of wall available per unit volume of core; the channel friction index scales the pressure lost along the channels for the same flow (for gentle laminar flow, friction rises quickly as channels narrow); the wall term index scales the pressure lost crossing the wall (thicker wall and less filtration area push it up). They ignore porosity, soot layers, ash and plug length.
| Combination | Pitch (mm) | Open channel width (mm) | Open fraction, all cells | Open fraction at inlet face | Solid fraction (thermal mass proxy) | Filtration area index | Channel friction index | Wall term index |
|---|---|---|---|---|---|---|---|---|
| 100 / 12 | 2.54 | 2.24 | 77.4 % | 38.7 % | 22.6 % | 0.75 | 0.40 | 1.33 |
| 100 / 17 | 2.54 | 2.11 | 68.9 % | 34.4 % | 31.1 % | 0.71 | 0.50 | 2.00 |
| 200 / 12 | 1.80 | 1.49 | 68.9 % | 34.5 % | 31.1 % | 1.00 | 1.00 | 1.00 |
| 200 / 14 | 1.80 | 1.44 | 64.3 % | 32.2 % | 35.7 % | 0.97 | 1.15 | 1.21 |
| 300 / 12 | 1.47 | 1.16 | 62.8 % | 31.4 % | 37.2 % | 1.17 | 1.81 | 0.86 |
What does the table teach?
- Raising density at the same wall thickness shrinks channels fast. From 200/12 to 300/12 the channel width falls from about 1.5 mm to about 1.2 mm, and the friction index nearly doubles, while the wall term falls because there is more wall area to share the flow.
- Two cores can share the same open fraction and differ in behaviour. The 100/17 and 200/12 rows both have 68.9 percent open area, yet 100/17 has about 30 percent less filtration area, twice the wall term and half the channel friction.
- Thicker walls cost more in the wall term and add mass. The 200/14 core carries more solid material than 200/12, which raises thermal mass but also the wall term.
- Cutting density and wall together lowers thermal mass. The 100/12 row holds about a quarter less solid material than 200/12 for the same volume, which matters for regeneration, as the next section shows.
The percentages are not performance predictions. They show why a supplier who quotes only CPSI has left most of the story out.
A quick way to check a supplier’s numbers
You can test a datasheet with a pocket calculator. Pitch in millimetres is 25.4 divided by the square root of CPSI. Open channel width is the pitch minus the wall thickness in millimetres (12 mils is 0.305 mm). The open fraction for all cells is the square of the width divided by the pitch. For 200/12, the pitch is 25.4 ÷ 14.14 = 1.80 mm, the width is 1.80 − 0.305 = 1.49 mm and the open fraction is (1.49 ÷ 1.80)² = 0.69. If a datasheet quotes an open frontal area that cannot be reproduced from its own cell density and wall thickness, ask why. The difference may be a rounded corner, a different definition or a mistake, and each deserves a sentence of explanation. Cells per square centimetre is CPSI divided by 6.45, for suppliers who quote metric figures.
Six things cell density moves
1. Back-pressure, in two parts
Pressure drop across a wall-flow filter comes from several places: flow contraction and expansion at the faces, friction along the channels, flow through the wall and flow through any soot layer. Cell density shifts the balance. A university study of how cell structure affects filter performance reports that, as cell density rises, filtration efficiency rises and loaded pressure drop falls while the clean pressure drop rises (ITM Web of Conferences, Tongji University). That echoes the table: a denser core has more wall area but narrower channels. A patent on thin-wall filters adds that, with thin walls, a density of 150 to 300 CPSI generally gave relatively low overall pressure drop by balancing clean and soot-loaded behaviour (US 8814974). There is a sweet spot, and it depends on wall thickness, porosity and the soot load you expect.
For a buyer, the key is to ask for both clean and loaded pressure-drop figures at your flow, not a single number. See how exhaust back-pressure affects a DG set.
2. Filtration surface and capture
More cells per square inch means more wall surface in the same volume, which spreads the flow across a larger filtering area. In the table, 300/12 offers about 17 percent more filtration area than 200/12 and 100/12 about a quarter less. More surface lowers the gas velocity through the wall and generally helps both pressure drop and capture. Efficiency also depends strongly on the pores and the soot layer, and a core’s clean-state capture can differ from its capture once a soot cake has formed. See RECD efficiency in new versus aged condition.
3. Soot capacity and downsizing
SAE work on filter downsizing shows the lever in action: by increasing cell density and reducing wall thickness, designers cut pressure drop in a soot-loaded filter, which allowed a filter volume reduction of around 20 percent in that programme while keeping performance (SAE 2007-01-0657). The lesson for buyers is that a smaller core is not automatically a worse one, and a bigger core is not automatically safer. What matters is the full design.
4. Ash storage and cleaning interval
Ash cannot be burnt away, and it builds up in the channels. Narrower channels give ash less room to settle before they start to choke. Designers have responded with asymmetric cell layouts that make inlet channels larger than outlet channels to store more ash, and a US Department of Energy presentation on such designs reports a significant increase in service interval compared with a standard symmetric design (US DOE DEER 2006). On a DG set with a modest oil consumption, ash may matter less than on a hard-working engine, but it still sets the cleaning interval. Ask how the supplier’s geometry handles ash. See soot versus ash in RECD regeneration and how to tell if an RECD filter is ash-loaded.
5. Thermal mass and regeneration peaks
A core with more solid material absorbs more heat per degree. University lecture notes on diesel filters compare 100 and 200 CPSI cordierite cores of the same size: the 100 CPSI core has lower thermal capacity, so its ceramic reaches higher temperatures when the same amount of soot burns (NPTEL lecture 30). Earlier SAE work on cell structure examined how wall thickness and cell density affect melting and thermal-shock failures during regeneration, alongside pressure drop (SAE 870010). In the table, the solid-fraction column is the proxy: 22.6 percent for 100/12 against 31.1 percent for 200/12.
For a DG set that may carry a heavy soot load before a burn, thermal mass is a safety margin. It is one reason low-density, thin-wall cores need good regeneration control. See RECD regeneration temperature and melted RECD filter cells: what a failure investigation should cover.
6. Catalyst, handling and cleaning
On a catalysed core, more geometric surface gives the washcoat more area, although a thicker coating also narrows channels and raises pressure drop. See catalysed versus uncatalysed RECD filters. Handling and cleaning methods also interact with geometry: narrow channels are less forgiving of poor cleaning, and delicate thin walls are less forgiving of rough handling. Ask the supplier which cleaning methods are approved for the exact core. See thermal cleaning questions for the provider.
Reading cell density against four duty situations
Cell density is a design choice, and the right choice leans on how the set is used. The notes below are prompts for a conversation with the supplier, not rules.
| Duty situation | Why geometry matters | Question to put to the supplier |
|---|---|---|
| Standby set with short test runs and rare outages | Soot may arrive in small amounts, but cool, light-load running leaves wet deposits that need heat to burn off. | How does this core and its regeneration control cope with long periods at light load? See RECD regeneration after wet stacking. |
| Prime-power set running for long hours | Total ash delivered over the years is large, so storage space and cleaning interval carry more weight. | What ash capacity does the geometry offer, and what interval do you expect at my oil consumption? |
| Set with frequent starts and load steps | Rapid changes in flow and temperature stress the ceramic, and thermal mass helps. | What is the core’s thermal mass relative to the soot limit, and how does the controller handle a load drop during a burn? |
| Set in a hot, dusty or confined location | Back-pressure margin is thin if the engine already breathes hard. | Can you show the loaded pressure drop at my flow and the maker’s back-pressure limit side by side? See RECD selection for generators in dusty industrial locations. |
A datasheet decoder: phrases that need a number
Marketing language often stands in for a figure that is missing. The following phrases are worth turning into questions.
- “Optimised cell structure.” Optimised for what: clean pressure drop, loaded pressure drop, ash storage or cost? Ask for the cell density, wall thickness and the design target.
- “High-efficiency filtration.” At what particle size or count, in what test, at what soot load and temperature? See RECD particle number versus particle mass.
- “Low back-pressure.” Clean or loaded, at what flow, and against which limit from the engine maker?
- “Long service life.” Hours, calendar years or cleanings, under what duty, oil consumption and regeneration control?
- “Ash-tolerant design.” Is the geometry asymmetric, and what is the stated ash capacity before cleaning?
- “Same as the leading brand.” Same cell density, wall, porosity, material and size, and where is the datasheet that proves it?
When a phrase cannot be turned into a number by the supplier, write that into your comparison sheet. Our guide to reading RECD case study results applies the same habit to results on a brochure.
Five myths about CPSI
| Myth | Reality |
|---|---|
| “Higher CPSI means a finer filter.” | Fineness is set by the pores in the wall. CPSI sets channel size and wall area. |
| “Lower CPSI always means lower back-pressure.” | Lower density widens channels but, with a thick wall, can raise the wall term. The table’s 100/17 core has twice the wall index of 200/12. |
| “Higher CPSI always lasts longer.” | Narrow channels can fill sooner with ash and are harder to clean. Asymmetric designs exist because symmetric ones have limits. |
| “The same CPSI means the same product.” | Material, wall thickness, porosity, plug design and size all differ. |
| “CPSI predicts life.” | Life depends on regeneration control, engine condition, oil and fuel, mounting and the duty cycle. |
The five-number specification line
Insist that every offer puts five numbers in one line, so that you compare like with like.
- Cell density and wall thickness: for example “200/12”, stating units.
- Cell shape and layout: square, or an asymmetric or other design; plugging pattern.
- Wall porosity and mean pore size, with the test method (usually mercury porosimetry). See the porosity article linked above.
- Core dimensions and volume: diameter, length and litres, plus the number of cores.
- Material and construction: cordierite, silicon carbide or another; monolithic or segmented. See silicon carbide versus cordierite and segmented versus monolithic RECD filters.
Then ask for four performance figures at your engine’s flow and temperature: clean pressure drop, pressure drop at the maximum soot load, ash capacity before cleaning and filtration efficiency with its test method. Without these, CPSI is trivia.
A worked comparison of two quotations
The following is an illustrative scenario, not a real customer or product. A school campus requests offers for a 250 kVA set. Two suppliers quote cores of the same material and roughly the same volume.
| Item | Quote A | Quote B |
|---|---|---|
| Cell density and wall | 200 CPSI, 12 mil | 100 CPSI, 17 mil |
| Material | Silicon carbide | Silicon carbide |
| Core volume | 34 litres | 34 litres |
| Stated pressure drop | “Low” | “Very low” |
| Price | Higher | Lower |
A first reading suggests B is the better deal: lower density, “very low” pressure drop and a lower price. Applying the table changes the picture. Using the indices, B has about 30 percent less filtration area, twice the wall term, half the channel friction and roughly the same solid fraction as A. Its pressure drop could be higher or lower depending on porosity, pore size and the soot layer, and “very low” has no unit.
The buyer sends the same four questions to both suppliers: clean and loaded pressure drop at the engine’s flow, ash capacity before cleaning, efficiency with its method and the pore data. Supplier A returns figures and a datasheet. Supplier B returns a statement that the figures are “available on request”. The buyer keeps B in the running and asks for a witnessed flow test or a reference installation. See questions to ask during an RECD factory visit and evaluating an RECD vendor reference installation.
The point is not that 200/12 beats 100/17. It is that the quote with numbers can be checked, and the quote without cannot.
Putting the question into an RFQ
A few lines in the request for quotation turn the topic into evidence. For each offered core, ask the supplier to state cell density, wall thickness, cell shape, porosity and pore size with method, core volume and material, and to provide clean and loaded pressure drop at stated flow and temperature, ash capacity, filtration efficiency with method and the approved cleaning methods. Add that offers lacking any of these will be treated as incomplete. Our guides on how to write a technical RFQ for an RECD project and tender specifications with measurable performance requirements give the surrounding structure.
Mistakes to avoid
- Treating CPSI as a quality score.
- Comparing CPSI without wall thickness.
- Accepting “low back-pressure” without a number, a flow and a condition.
- Ignoring ash. The cleaning interval depends on it.
- Forgetting thermal mass when a core is thin-walled and low-density.
- Comparing price per litre across different geometries.
- Skipping the check on approved cleaning methods.
Questions people ask
Which CPSI is best for a DG set?
There is no single best value. Patents and papers describe workable ranges from about 100 to 350, with 150 to 300 often cited for thin-wall designs, but the right choice depends on wall thickness, porosity, engine flow, duty and ash. Ask the supplier to justify the geometry for your engine.
Does a higher CPSI filter capture more particles?
It often provides more wall area, which can help, but capture depends mainly on the pores and the soot layer. Ask for efficiency data and its test method.
Is a lower CPSI filter easier to clean?
Wider channels can be easier to access, but cleaning depends on the method, the deposit and the core’s strength. Ask which methods are approved for your core.
What does 200/12 mean?
It means 200 cells per square inch with walls 12 mils (0.012 inch) thick.
The takeaway
CPSI is a geometry figure that must be read with wall thickness, porosity, size and material. It moves back-pressure, filtration area, ash storage, thermal mass and cleaning behaviour, often in opposite directions. Demand the five-number specification line, ask for clean and loaded pressure drop, ash capacity and efficiency at your flow and never compare offers on CPSI alone. For help applying this to a real project, the Aceget team can discuss your set, and the FAQ and retrofit emission control devices pages give background.
Related Reading
- RECD Filter Porosity: Why It Cannot Be Judged from Appearance
- RECD Filter Face Area vs Filter Length: Understanding Design Trade-Offs
- Silicon Carbide vs Cordierite RECD Filter Substrate
- Compare RECD Designs: Ash Capacity and Service Access
- How to Write a Technical RFQ for an RECD Project
Sources
- US patent 8814974: thin-walled porous ceramic wall-flow filter
- ITM Web of Conferences: effect of cell density and wall thickness on DPF performance
- SAE 2007-01-0657: minimising filter volume by design optimisation
- US DOE DEER 2006: asymmetric cell technology and ash storage
- NPTEL lecture 30: diesel particulate filters, cell density and thermal capacity
- SAE 870010: effect of cell structure on regeneration failure
[…] RECD Filter Cell Density: What Does CPSI Mean for Buyers? […]
[…] RECD Filter Cell Density: What Does CPSI Mean for Buyers? […]