Exhaust Leaks Around an RECD: Symptoms and Inspection Points

Exhaust leaks have a way of hiding in plain sight. A thin black streak on a flange, a faint ticking at idle, a smell that comes and goes in the plant room: each one is easy to dismiss until the day the readings stop making sense. Around a retrofit emission control device (RECD) the stakes are a little higher than on a plain exhaust, because the device adds joints, sensor ports and a heavy, hot body that expands and contracts every time the set runs.

This article is an inspection guide. Rather than listing causes in the abstract, it asks you to walk the exhaust route, station by station, from the engine to the stack outlet. At each station it says what to look for, what you might hear or smell, and why a leak there matters. Then it covers safe test methods, a triage table that sorts leaks by urgency, and the repairs that last.

The scope is the exhaust path and its sensing connections. If your problem is a whistle, see our guide on whistling after RECD installation. If it is a rattle, see rattling inside an RECD.

Why a leak near an RECD is not a minor issue

On a plain silencer, a small leak is mostly a noise and nuisance problem. With a filter in the path, a leak changes more than that.

It is a health and safety problem. Exhaust contains carbon monoxide, which has no smell, and fine particulate. A leak inside a plant room puts both into the space where staff work. The smell you notice, which comes from other exhaust components, is a warning but not a guide to how much carbon monoxide is present. Treat any suspected leak in an enclosed space as a ventilation and safety matter first.

It distorts what the controller sees. If gas escapes upstream of the filter, less gas passes through it, so differential pressure (ΔP) reads lower than it should for the load, and temperature at the filter can drop. The device may then appear “cleaner” or cooler than it is, and regeneration decisions may be wrong. If a leak is downstream, the gas that escapes has already been filtered, but pressure and temperature readings near the leak can still be disturbed. Our article on separating a sensor fault from an RECD performance problem shows how leaks and faulty sensors can mimic each other.

It can feed air into the system. Exhaust flows in pulses, and on some engines the pressure at a joint briefly falls below atmospheric between pulses. A leaking joint can then draw in a little air, which changes oxygen content and can cool the gas. That matters for sampling accuracy and for catalyst behaviour.

It can mean something is moving. A leak is often the first visible sign that a joint is under strain from thermal expansion, a missing support or a loose fastener. Fixing the leak without understanding the strain means it will return. See thermal expansion planning for RECD exhaust connections.

Reading the evidence: five clues a leak leaves

Before the station-by-station walk, learn the clues, because they repeat at every station.

  1. Soot streaks. Black or brown streaks radiating from a joint show where gas escaped and the direction it travelled. A streak that fans outward from the edge of a flange gasket is the classic sign. Dry, powdery soot suggests a leak that is recent or ongoing, while oily, glossy deposit suggests wet soot, fuel or condensate.
  2. Clean patches. A pulsing leak can scour a small clean patch in an otherwise sooty area, because the jet blows the deposit away.
  3. Discolouration and heat marks. A blue or rainbow tint on metal near a joint indicates localised heating from escaping hot gas. Paint blistering or insulation blackening points the same way.
  4. Sound. A ticking, puffing or hissing noise that follows engine speed or load. A fine leak at a small orifice can whistle, which is discussed in the whistling article linked above.
  5. Smell. Exhaust smell near a joint, or a change in smell when the set is loaded. Do not rely on smell as a safety measure.

One more principle: leaks are at their worst when the system is hot and under load, and at their easiest to find when the system is cold. A diesel-parts guide on exhaust inspection suggests starting with a cold visual inspection and then listening at idle, since many leaks are easiest to hear before the metal expands fully with heat. The same logic applies to a retrofit.

Walking the route: ten stations

Work from the engine to the stack. Use a torch and a camera, and photograph every station before touching anything. Carry out the inspection only when the exhaust is cold and the set is isolated, unless a station says otherwise.

Station 1: Turbocharger outlet and expansion piece

What is here. The connection between the turbo outlet and the first section of exhaust, often with an expansion piece or a short flexible section.

Look for. Soot around the turbo outlet flange, a gasket edge visibly extruded, cracked flange welds and signs of recent disturbance, such as scratched bolt heads from previous work.

Why it leaks. This joint sees the highest temperature and vibration. Gaskets here are often one-use and deform after a heat cycle.

What a leak does. A leak this close to the engine can waste energy that the turbine would use, and a pre-filter leak lowers flow through the RECD.

Station 2: Flexible bellows

What is here. A convoluted flexible section that absorbs engine movement and thermal expansion. See flexible bellows in an RECD exhaust system.

Look for. Cracks in the convolutions, particularly at the valleys, soot weeping from the weave of a braided cover, stretched or twisted sections, and bellows installed in compression or extension beyond their rating. Check that internal liners face the right way.

Why it leaks. Fatigue from vibration, misalignment, installing a bellows as a pipe support, or movement beyond its design.

What a leak does. Bellows leaks tend to be large and noisy, and they may appear only when the set is hot.

Station 3: Pre-filter pipe run and bends

What is here. The piping between the engine side and the RECD inlet, possibly with welded or flanged joints and supports.

Look for. Weld cracks near supports, soot at clamp joints, slip joints that have walked apart, and mitred bends with thin welds. Check that supports are carrying weight and not leaving the load to the joints. Our guide on RECD exhaust bends, reducers and layout review explains why bends concentrate stress.

Why it leaks. Unsupported weight, thermal growth that has nowhere to go, or poor weld quality.

Station 4: RECD inlet flange and cone

What is here. The connection between the pipe and the RECD, often with a gasket and a cone or transition piece.

Look for. Soot at the flange edge, bolt stretch (uneven gaps between flange faces), crushed or missing gaskets, and misaligned faces that were pulled together by bolts. Check whether bolt heads show signs of repeated tightening.

Why it leaks. The RECD is heavy and its growth on heating can be substantial. If the support frame is rigid and the pipe is rigid, the flange takes the difference.

Station 5: RECD body, canning seams and doors

What is here. The canister itself: seams, weld lines, access doors or covers, drain plugs, lifting lugs welded to the shell.

Look for. Soot at seams, around door gaskets and drain plug threads, bulging or discolouration of the shell, and weld cracks at lugs. A fresh black ring around a door gasket is a standard find after a service visit, if the gasket was reused or the bolts were not torqued in sequence.

Why it leaks. Reused gaskets, uneven tightening, thermal cycling, and door covers that were not properly seated after service.

What a leak does. A leak through the body can let raw gas out before it passes through the whole filter. In a canister with a leaking door on the inlet side, ΔP will read low for the load.

Station 6: Sensor ports, thermocouples and pressure taps

What is here. The small penetrations into the exhaust path: temperature sensors, pressure tap nipples, sampling ports, and sometimes a lambda or other probe.

Look for. Soot around compression fittings, loose sensor bodies, sampling port caps that are missing or not sealed, and cracked tubing at the tap. A leak at a pressure tap is subtle, because it changes the reading rather than making noise. Our article on RECD temperature sensor placement explains where sensors belong, and the guide to pressure sensors versus pressure switches covers how taps are used.

Why it leaks. Fittings loosen with vibration, are removed for calibration and not refitted properly, or are reassembled with the wrong sealing washer.

What a leak does. A leaking pressure tap reduces the measured pressure at that point and may create false ΔP readings. A leaking sampling port can bias emission test results, a point developed in our article on exhaust sampling location and test results.

Station 7: RECD outlet flange and transition

What is here. The mirror image of Station 4, on the clean side.

Look for. The same signs. Because the gas here has been filtered, deposits are lighter, so a soot streak on this side is a particularly important clue. Heavy black deposit at the outlet flange suggests soot is passing through or around the filter. Compare with the story in our article on black smoke after RECD installation.

Station 8: Silencer inlet, body and outlet

What is here. The existing or new silencer, with its flanges, drain, body seams and mounting.

Look for. Soot at the inlet and outlet flanges, rust-through at the bottom (where condensate collects), weeping drains, and failed internal baffles that can create noise and a restriction. Condensate can corrode the silencer from within, and a weeping drain is easy to mistake for a flange leak. Our guide to reusing existing exhaust pipework in an RECD retrofit lists what to check on old parts.

Station 9: Stack, wall penetration and rain cap

What is here. The route through the wall or roof to the outdoors, with any sleeves, weather flashing and a rain cap.

Look for. Soot where the pipe passes through a wall or roof sleeve, which would indicate a joint inside the sleeve. Check the rain cap for corrosion and for moisture running down into the system, which links to the topic of protecting an RECD against rainwater and condensation.

Station 10: Supports, hangers and insulation

What is here. The structure that carries and holds the whole run, and the insulation or heat shields that surround it.

Look for. Hangers that have lost tension, supports not touching the pipe, insulation blackened or soaked in a pattern that mirrors a leak, and shields rubbing the pipe. Insulation that is stained from the inside is a good indicator of a leak under it. Our guide on RECD insulation and heat shields describes the arrangement.

The triage table

Not every leak needs the same response. Use the table to decide what to do and how quickly.

FindingLikely severityWhat to do
Faint dry soot at a flange edge, no sound, no smell, stable over weeksLowPhotograph, mark the edge with a paint pen, re-inspect at next service
Soot streak that has grown since last inspectionModeratePlan a cold re-torque or gasket replacement; check supports and alignment
Audible puff or tick at idle, exhaust smell in plant roomHighTreat as urgent; check ventilation, limit running, repair soon
Large bellows crack, loud noise, visible gas jetVery highShut down safely, isolate and repair before further running
Leak at a pressure tap or sensor fittingModerate (data impact)Re-seat or replace the fitting; note affected readings
Heavy soot on the clean side of the filterHigh (possible bypass)Escalate to the supplier; see the smoke article
Oily weeping at a silencer drainLow to moderateConfirm it is condensate and not a joint leak; clean and re-check

Safe test methods

Several methods find leaks without guessing. Which ones you use depends on whether the system is cold or hot, and on what you have access to.

Cold visual inspection

The cheapest method. With the system cold and isolated, inspect each station with a torch. Compare soot patterns with the previous inspection’s photographs. This finds most large leaks and many small ones.

Listening on idle and under load

With a clear plan and a second person, run the set at idle and listen along the route. A length of hose with one end to the ear and the other near a joint can help locate a leak by sound. Keep clear of rotating parts, hot surfaces and the exhaust outlet. Many leaks are quietest when fully hot, so repeat the listening at different temperatures.

Soap solution on a cold, pressurised system

On a cold system that can be safely blanked off and gently pressurised with air, a soap solution sprayed on joints will bubble at a leak. This does not apply to a hot exhaust, where soap will boil off and an unsupervised pressure test can be unsafe. A pressurised test should only be done to a pressure and in a manner approved by the supplier, with all sensors and the filter’s limits respected.

Smoke-machine testing

Some truck makers use a smoke machine to find leaks in after-treatment systems. Their service bulletins note that long systems should be tested in sections, before and after the filter separately, and that a smoke test is for locating leaks, not for judging the condition of the filter. If you use this method, follow the instrument maker’s instructions and test the sections separately. Our article on safe access to sampling ports on a tall chimney may help with access.

Thermal imaging

A thermal camera on a running system shows hot spots where gas escapes, or cold spots where air enters. It also reveals missing insulation. It cannot see inside, and the reading depends on surface emissivity, so use it as a guide.

Ultrasonic leak detection

An ultrasonic detector picks up the high-frequency noise of a leaking gas jet, even when the plant room is noisy. It is good for finding small leaks on a running set at a safe distance.

Pressure and temperature comparison

Compare ΔP and temperature at the same load before and after a suspected leak. A drop in ΔP at an unchanged load, or a temperature at the inlet that falls without a change in load, is a data-based clue. See comparing RECD pressure readings at different generator loads.

Carbon monoxide and ventilation

Because carbon monoxide has no smell, do not use your nose to decide whether a plant room is safe. A leak inside a building is a reason to check ventilation, and where appropriate a calibrated carbon monoxide detector, before anyone works near the set. Our article on whether an RECD makes a DG set safe indoors explains what a filter does and does not change, and workplace air monitoring and exposure around an RECD covers monitoring. If anyone feels unwell near a set with a suspected leak, treat it as an emergency, get them into fresh air and follow your site procedure.

Repairs that last

A leak that returns within weeks was never properly fixed. The following habits reduce repeat leaks.

  • Replace one-use gaskets and seals. Reusing a crushed gasket is a common reason for a leak that returns after a service. Use the gasket type the supplier specifies for temperature and pressure.
  • Clean the faces. Remove old gasket material and carbon from flange faces. A rough, sooty face will not seal.
  • Torque in sequence and re-torque after a heat cycle. Tighten bolts in a cross pattern to the specified torque, run the set to temperature, let it cool and check torque again, as the supplier recommends.
  • Fix the cause, not only the leak. If a flange leaks because the pipe is under strain, look at supports, expansion allowance and alignment. If a bellows has failed, check why: misalignment, wrong orientation or being used as a support.
  • Do not seal with tapes, putties or paint on a hot exhaust. They fail quickly, hide evidence and may release fumes.
  • Record what you did. Note the date, the station, the part replaced, the torque used and photographs. Our guide to the RECD event log suggests a format, and updating drawings and records after exhaust modifications explains why changes must be documented.
  • Verify afterwards. Re-inspect after a loaded run, compare soot patterns and ΔP at the same load, and confirm the leak has stopped.

A worked illustration: the leak that lowered ΔP

The following is an illustrative scenario, not a real customer. A pharmaceutical plant has a 320 kVA set with an RECD installed six months earlier. A technician notices a faint black streak at the inlet flange during a routine round. Over the next two months, the controller’s ΔP at 60% load falls from 31 mbar to 26 mbar, even though regeneration logs show no recent cycles. At first this is read as a sign of a “cleaner” filter.

The walk. During a planned shutdown, the technician follows the ten stations. At Station 4 the gasket has been squeezed out on one side, leaving a gap, and bolt heads show uneven tightening. At Station 3 a pipe hanger is loose, so the pipe is hanging on the flange. There is soot on the insulation around the flange, soaked on the underside.

The triage. The streak has grown since the last photograph, so the leak is moderate. The falling ΔP suggests that some flow is escaping before the filter. The soot stains show a path onto the insulation.

The repair. The team replaces the gasket with the specified type, cleans the faces, re-hangs the pipe so the supports carry the weight, torques the bolts in sequence and re-torques after a heat cycle. They replace the soaked insulation.

The check. On the next loaded run ΔP at 60% load returns to about 31 mbar. The streak does not reappear over the next quarter. The lower ΔP that had looked like good news was a symptom of a leak.

A short inspection routine to keep in the file

  • Every week: a quick walk past the set while running, looking and listening for new soot, noise or smell.
  • Every month: a cold visual inspection of Stations 1 to 10 with photographs, compared with the last set.
  • After any service or repair: a check of every joint disturbed, a loaded run and a second look when cool.
  • After any exhaust modification: update the drawing and the inspection list.
  • Annually: a more detailed inspection with bolts re-torqued, gaskets replaced as scheduled and supports checked.

For the larger context of routine care, see the RECD maintenance guide.

Frequently asked questions

Is a small soot stain at a flange acceptable?

A faint, dry stain that does not change and that comes with no noise or smell may be tolerated briefly, but it should be photographed, marked and repaired at the next opportunity. Gas that has found a path will usually widen it.

Can an exhaust leak damage the filter?

Indirectly. A leak upstream can lower the temperature and flow in the filter, which affects regeneration, and a hot jet can damage nearby insulation, wiring and sensor lines. It can also mislead the controller. A leak is not usually the direct cause of a cracked substrate.

Why do leaks appear only after a service visit?

Because disturbed joints are the most likely to leak. A reused gasket, uneven torque, a missed bolt or a door seated wrongly can all produce a new leak. Ask for a post-service check of every joint that was opened. Our article on auditing an RECD service report for missing information explains what a good report records.

Can I use exhaust sealant paste on a flange?

Only if the supplier approves a specific product for your temperature and gasket type. Many pastes fail when hot or leave residues that make future sealing harder.

Who is responsible if a new installation leaks?

It depends on the contract and on the cause. See customer and installer responsibilities in an RECD project. Documentation of the leak, photographs and the condition at handover help.

Bringing it together

Exhaust leaks around an RECD show up as soot trails, sounds, smells and readings that no longer agree. Walk the route in ten stations, use the five clues at each one, triage by severity and choose the safest test for the situation. Repair the cause as well as the leak, document the work and verify the result under load.

If you would like help reviewing a layout or an inspection list for your own set, browse our retrofit emission control devices, the FAQ or contact the Aceget team.

Related Reading

Sources



2 Comments