Can Crankcase Ventilation Routing Affect an RECD Installation?

Nobody puts the engine breather on the first page of an RECD retrofit drawing. The drawing shows the exhaust pipe, the new filter housing, the supports, the sensors and perhaps the cable tray. The crankcase breather is a small hose or a short pipe on the side of the engine, and it is easily overlooked. Yet it is the engine’s only exit for blow-by gas, and its route decides where oil mist ends up, how much pressure builds in the crankcase and whether the retrofit quietly makes the engine’s oil problems worse.

Retrofit work is exactly the kind of work that disturbs breathers. Space is tight, so hoses are shortened or bent to clear a new support. A canopy panel is cut, and the breather outlet now points somewhere different. A pipe run is lagged, and a hose finds itself sitting against hot insulation. None of this looks significant on the day. Three months later the oil needs topping up more often, there is an oily film on the lagging or the turbo seal is leaking, and the RECD pressure is higher than the supplier predicted.

This article makes the breather visible. We start with what the crankcase ventilation system does and the ways engines are built to route it. We then describe six routing types and what each means for a retrofit, give you a ten-point hose walk to run before and after installation, set out the changes an RECD project is most likely to cause and show how to verify the outcome with simple measurements. A worked scenario and a drawing-and-RFQ checklist follow. The advice is general. The engine maker’s ventilation design and limits take priority, and changes to the ventilation system belong to qualified technicians.

What crankcase ventilation does

Every piston ring leaks a little. Combustion gases that slip past into the crankcase are called blow-by, and they carry oil mist, unburned fuel and water vapour. If that gas is not removed, crankcase pressure rises, oil is pushed out through seals and gaskets and the engine becomes dirty and unreliable.

A filter maker explaining the basics describes two ways of dealing with it. If the blow-by gas is released directly to the surrounding air, the ventilation is called open. In modern engines the trend is towards closed ventilation, where the gas is returned to the engine’s intake after an oil separator has removed the droplets, and the separated oil goes back to the sump (MANN+HUMMEL). Patent descriptions of such systems show the usual arrangement: the cleaned gas returns to the intake flow between the air filter and the turbocharger, mixes with fresh air, is compressed by the turbo and then cooled in the charge-air cooler (USPTO publication on an oil separator).

Two consequences follow.

  1. In a closed system, the breather is part of the air path. Whatever the separator fails to catch ends up on the compressor wheel, in the charge-air cooler and in the cylinders. A service-trade article on neglected closed ventilation systems describes how oil-saturated blow-by vapour fouls the turbo inlet, charge-air piping and the rest of the intake over time, without ever triggering a dramatic warning (Auto Service World).
  2. In an open system, the breather is a separate emission source. The mist leaves the engine without passing the RECD, so the filter cannot reduce it. It can settle on nearby surfaces, including lagging and the filter housing.

Blow-by volume rises as an engine wears. Our article on whether engine blow-by affects RECD maintenance needs explains the condition side. This article is about the pipework.

Why routing affects the RECD

The link between the breather and the RECD is indirect, and it runs through four mechanisms.

Mechanism 1: oil in the intake becomes ash in the filter. Oil mist that enters the air path is burned in the cylinders. The organic part burns and the additive metals remain as ash, which collects in the filter. A poorly routed or overloaded closed system therefore raises ash loading. See soot versus ash in RECD regeneration.

Mechanism 2: crankcase pressure pushes oil past seals. If the route restricts flow, crankcase pressure rises. A turbo manufacturer’s diagnostic page lists excessive crankcase pressure and correct breather function among the checks before a turbocharger is condemned (Garrett), and a vehicle-maker bulletin warns that a blocked ventilation hose can raise crankcase pressure and cause turbo oil leakage, while noting that some apparent leakage is simply normal behaviour of a closed ventilation system (NHTSA-filed Isuzu bulletin). Oil leaking from the turbo on the turbine side goes straight to the RECD. See turbocharger oil leakage and RECD contamination.

Mechanism 3: mist near hot parts and near intakes. An open breather that discharges onto a hot exhaust component creates smoke and a fire risk. One that discharges near an air inlet or a canopy louvre can be drawn back into the intake. After a retrofit, the new filter housing and its lagging are exactly such hot, oil-catching surfaces.

Mechanism 4: a changed route can change the engine’s air and exhaust balance. If a hose is lengthened, narrowed or looped, flow resistance changes. Closed systems are designed around a controlled pressure at the return point. Changing the route can change the pressure the separator sees.

Six routing types and what each means for a retrofit

Ask the engine maker which one your engine uses. If you cannot identify it from the manual, trace the hose.

TypeDescriptionMain RECD retrofit concernWhat to protect
R1. Open vent at the engineA short pipe or hose from the rocker cover or crankcase, discharging near the engineNew hot surfaces and lagging close by; mist deposits on themKeep the outlet clear of the RECD, lagging and hot pipes; photograph before and after
R2. Open vent via a long hoseA hose leads the vent to a point outside the engine, perhaps through the canopy or wallRetrofit work may cut, kink or relocate the hoseSlope, diameter, drain-back and outlet position
R3. Closed, with a maker-supplied separatorBlow-by passes through an integrated separator and returns to the intake before the compressorDisturbing the return hose, the drain-back line or the intake pipeReturn hose length, diameter and routing; separator drain; intake air filter downstream connections
R4. Closed, with an added or aftermarket separatorA catch can or separator fitted laterUnknown design basis; easily bypassed or blockedMaker approval and a service record
R5. Shared headerSeveral engines or cylinder banks join into one vent lineRetrofit work on one set may change the shared lineWhich set owns the line and who services it
R6. Vent routed into the exhaust or silencerA non-standard arrangement sometimes seen on older sets or field modificationsOil mist goes straight into the RECD; hot gas can come back toward the crankcaseDo not create or retain without written approval from the engine maker and the RECD supplier

R6 deserves a firm word. Directing crankcase vapour into the exhaust upstream of a filter sends oil mist directly to the core, adds ash with every hour of running and exposes the crankcase to exhaust pressure pulses. It is not a design choice to adopt during a retrofit. If you find it on an existing set, raise it with the supplier and the maker before the RECD is fitted.

The ten-point hose walk

Walk the breather route from the engine to its end, with the engine stopped and cool, and again with it running at steady load from a safe distance. Do it before the retrofit to create a record, and again after it. Photograph each point.

  1. Source. Where does the route leave the engine? Note the connection, any valve and any separator housing.
  2. Separator condition (closed systems). Is it the maker’s unit? Any signs of leaking or saturation? Is its drain-back line free and sloping towards the engine?
  3. Hose material and temperature rating. Is it rated for hot oil vapour? Does it sit near hot exhaust, the turbo or the new RECD? Softening or cracking is a warning.
  4. Diameter and length. Compare with the maker’s drawing. A narrower or longer hose adds resistance.
  5. Slope and low points. The hose should drain back toward the engine, not collect oil in a sag. A trapped liquid slug restricts flow and can block the line.
  6. Bends and kinks. A tight bend or a hose squeezed by a new support, cable tie or clamp closes the passage.
  7. Clamps and joints. Leaks draw unfiltered air into a closed system or spray oil mist in an open one.
  8. Termination. For open vents, where does the outlet point, and what is within range? Hot surfaces, lagging, intake louvres, cable trays and walkways all matter. For closed systems, where does the return enter the intake, and has anything been changed near that point?
  9. Rain and debris protection. An open outlet needs a guard that does not restrict flow. A blocked guard raises crankcase pressure.
  10. Service access. Can the separator, hose and clamps be inspected and replaced without dismantling the RECD or its supports?

Record the findings in a table: point, condition, photo reference and who checked. Keep the before and after tables together.

What an RECD retrofit is most likely to disturb

From the pattern of typical retrofit tasks, six disturbances are worth listing on the project plan.

Retrofit taskHow it can disturb the breatherWhat to do
Cutting and rerouting exhaust pipeHose or separator in the way, so it is moved or cutMark breather hoses on the general arrangement drawing as no-go items
Installing new supports and bracketsBrackets pinch or chafe hosesCheck clearances; use rubber-lined clamps
Fitting insulation or heat shieldsHose ends up against hot lagging, or the outlet discharges onto itProvide a clearance envelope and test by thermal camera. See RECD insulation and heat shields
Modifying a canopyOutlet moved, blocked or directed toward louvresRe-plan the outlet position. See fitting an RECD inside an acoustic canopy
Moving the air intake or air filterThe closed-system return point changesKeep the return arrangement per the maker’s design
Adding sensors and cablingCables are tied to hoses; hoses are deflectedRoute cables separately. See RECD cable routing near hot exhaust lines

Our article on what to include in an RECD general arrangement drawing can be extended with a breather layer: hose, separator, termination and the clearances required.

Symptoms that point back to routing

If the following appear after a retrofit, include the breather in the investigation.

SymptomPossible routing link
Rising oil consumption with no change in engine conditionSeparator bypassed, saturated or drained badly; mist entering the intake
Oil film in the charge-air pipe or coolerClosed-system carry-over
Oil leaking at crankshaft seals, valve cover or dipstick tubeRaised crankcase pressure from a restricted route
Oil at the turbine outlet or in the RECD inletTurbo seal leakage under crankcase pressure
Oily film on RECD lagging or the canopyOpen vent discharging in the wrong direction
Smoke or smell when the set is hotMist landing on hot surfaces
Faster ash accumulation than predictedMore oil entering the cylinders
Visible mist at the breather outlet at steady loadHigh blow-by or a saturated separator

Because the symptoms overlap with worn rings and turbo faults, use the routing audit to rule the pipework in or out before assuming engine wear. See also our guide on RECD issues after an air-intake restriction, since intake and ventilation problems often arrive together.

Verifying the outcome with simple measurements

Take the following before and after the retrofit, at the same load and the same engine temperature.

  • Crankcase pressure with a manometer on the dipstick tube or the designated port, by the maker’s method. A technician should do this.
  • Oil level and consumption over a defined period, with a written method.
  • Breather outlet observation: mist, dripping, staining. Photograph at steady load.
  • Charge-air path inspection at the first service after the retrofit: film in the pipe, on the cooler or on the compressor housing.
  • Surface temperature near the outlet and hose with a thermal camera or infrared thermometer.
  • RECD pressure at a reference load and the loading rate over the first hundred run hours. See comparing RECD pressure readings at different generator loads.
  • A used-oil sample after the first interval, for soot, fuel and wear metals.

Compare the numbers with the maker’s limits and with the pre-retrofit values. A change that cannot be explained by the retrofit scope is a reason to inspect the route.

A worked illustration: the hose that was moved for a bracket

The following is an illustrative scenario, not a real customer. A food-processing plant retrofits an RECD to a 400 kVA set with a closed crankcase ventilation system and a maker-supplied separator. The installer needs room for a new support bracket and re-routes the breather return hose, shortening it slightly and forming a loop under the bracket to avoid a hot pipe. No one checks the hose against the maker’s drawing.

Weeks 1 to 3. The set runs normally. The RECD pressure at the reference load matches the supplier’s forecast.

Week 6. The operator notices oil on the lagging near the turbine outlet and a higher oil top-up rate. RECD pressure is climbing slightly faster than forecast.

Hose walk. The technician finds a sag in the hose where it loops under the bracket. Oil from the vapour has pooled in the low point, partly blocking the flow, and the hose touches the hot pipe at one point and has softened. Crankcase pressure measured at steady load is above the maker’s limit. The separator drain-back line is also partly crushed by the new bracket.

Reading. Raised crankcase pressure is pushing oil past the turbo seal, and part of the mist is not draining back, so more oil is being drawn into the intake and burned. Both effects add oil to the RECD side.

Fix. The hose is replaced to the maker’s length and diameter, with a continuous slope and a heat-rated sleeve, the drain-back line is freed and the bracket is relocated. The turbo area is cleaned, and the supplier inspects the RECD, finding oil-wetted soot without damage, and cleans it. Crankcase pressure returns within the limit, oil consumption falls and the RECD pressure rise per hundred hours returns to forecast.

Lesson. A bracket and a hose each did what they were told. Nobody owned the interface between them. The plant adds a “breather and separator” line to the commissioning checklist and the hose walk to the acceptance test. See RECD trial installation acceptance criteria.

Writing breathers into the RFQ and the drawing

If you are planning a retrofit, put the breather into the paperwork before the contractor arrives. Useful clauses include:

  • The contractor shall identify the crankcase ventilation type of each engine and record it on the general arrangement drawing before work begins.
  • Breather hoses, separators and drain-back lines are protected items. They shall not be cut, shortened, re-routed or clamped without written approval from the engine maker or its authorised dealer.
  • Before and after photographs and a completed hose-walk table are required deliverables.
  • Open breather outlets shall not discharge onto lagging, the RECD housing or hot pipework, nor toward air intakes.
  • No crankcase vent shall be connected to the exhaust system upstream or downstream of the RECD without written approval from the engine maker and the RECD supplier.
  • Crankcase pressure and oil consumption shall be measured before and after, with results reported.

Our guides on how to write a technical RFQ for an RECD project, customer and installer responsibilities and common RECD installation mistakes to avoid show where such clauses belong.

Mistakes to avoid

  1. Leaving the breather off the drawing. If it is not drawn, it is not protected.
  2. Treating a hose as a “flexible item” that can be bent to suit.
  3. Using an unrated hose near new hot surfaces.
  4. Pointing an open outlet at lagging or at an intake.
  5. Capping or restricting a breather to cure mist. That raises crankcase pressure.
  6. Adding a catch can without maker approval.
  7. Connecting the vent to the exhaust to hide the mist.
  8. Skipping the baseline. Without a before measurement, nobody can tell whether the retrofit changed anything.

Questions people ask

Does the RECD treat crankcase mist?

Not if the mist leaves through an open vent. The filter treats the exhaust stream. On a closed system, the mist that is not caught by the separator enters the engine and, once burned, reaches the filter as soot and ash.

Can I route the breather into the exhaust to avoid mist?

Do not do it without written approval from the engine maker and the RECD supplier. It sends oil mist directly to the filter and exposes the crankcase to exhaust pressure.

How often should the separator be serviced?

Follow the maker’s schedule, and bring it forward if oil is found in the charge-air path or if oil consumption rises.

My engine has an open breather. Do I need to worry?

Pay attention to where it discharges, how much mist it releases and whether the retrofit has changed its surroundings. A visible increase in mist suggests more blow-by, which is also a filter-maintenance signal.

Who is responsible for the breather during a retrofit?

Name an owner in the project plan. The engine maker or dealer decides on any change to the system, and the installer must not alter it without approval.

The short version

The crankcase breather is the part of the engine most likely to be disturbed by an RECD retrofit and least likely to be on the drawing. Identify the routing type, walk the hose before and after, protect it as a no-go item, keep outlets away from hot surfaces and intakes, never vent into the exhaust and measure crankcase pressure and oil consumption to prove nothing has changed. If you would like help adding a breather layer to your retrofit drawing or acceptance test, you can browse our retrofit emission control devices, read the FAQ or contact the Aceget team.

Related Reading

Sources



Leave a Reply